County approved permit plans are required on site for all inspections including reinspections.
For new dwellings and additions where a soils report is required, a complete copy of the report must be provided on site for this inspection.
This POURED WALL inspection is required prior to placing concrete.
- All forms are to be in place.
- All reinforcement required by the approved plans is to be complete and a safe method of inspection such as an OSHA approved ladder or scaffolding shall be provided by the general contractor or a representative of the general contractor. Where reinforcing steel (re-bar) is required, re-bars are to be secured to their supports and to adjoining re-bar so that they cannot be displaced (securely tied, etc.).
- Walls (forms) are to be the size and depth shown on the approved plans. All pier footings shall be located and aligned per the approved plans if applicable.